Search results for "screw fixation"

showing 6 items of 6 documents

Clinical pathways for fragility fractures of the pelvic ring: personal experience and review of the literature

2014

AbstractFragility fractures of the pelvic ring (FFP) are increasing in frequency and require challenging treatment. A new comprehensive classification considers both fracture morphology and degree of instability. The classification system also provides recommendations for type and invasiveness of treatment. In this article, a literature review of treatment alternatives is presented and compared with our own experiences. Whereas FFP Type I lesions can be treated conservatively, FFP Types III and IV require surgical treatment. For FFP Type II lessions, percutaneous fixation techniques should be considered after a trial of conservative treatment. FFP Type III lesions need open reduction and in…

Aged 80 and overmedicine.medical_specialtybusiness.industryFrail Elderlymedicine.medical_treatmentReview ArticleSurgeryScrew fixationFracture Fixation InternalFractures BoneExternal fixationSacroiliac screwPelvic ringFracture fixationOrthopedic surgeryCritical PathwaysmedicinePercutaneous fixationHumansInternal fixationSurgeryOrthopedics and Sports MedicinePelvic BonesbusinessAgedJournal of Orthopaedic Science
researchProduct

EMG-guided percutaneous placement of cement-augmented pedicle screws for osteoporotic thoracolumbar burst fractures

2017

Background: Percutaneous techniques have increasingly gained popularity in recent years. The application of technological innovation, including neuromonitoring techniques, has the potential to increase the safety and efficacy of these procedures. Methods: Thirty patients suffering from osteoporotic dorsolumbar burst fracture were prospectively enrolled in this study. The patients underwent percutaneous fenestrated pedicle screw fixation augmented with polymethylmethacrylate (PMMA) injection. A novel surgeon-dedicated neuromonitoring device was used in order to increase the safety and the accuracy of the screw insertion. A second group of 30 patients who did not undergo neuromonitoring durin…

MalePercutaneousPercutaneous techniquesPercutaneous pedicle screw fixationNeuromonitoringFracture Fixation Internal0302 clinical medicinePedicle ScrewsFracture FixationProspective StudiesPedicle screwTomographyMinimally invasive spinal surgery030222 orthopedicsCementoplastyLumbar VertebraeSettore MED/27 - NeurochirurgiaSpinal FractureBone CementsMiddle AgedX-Ray Computedmedicine.anatomical_structuresurgical procedures operativeBurst fractureSpinal FracturesFemaleHumanmusculoskeletal diseasesmedicine.medical_specialtyOsteoporotic FractureLumbar vertebraeCement augmentationThoracic VertebraePedicle Screw03 medical and health sciencesBone CementBurst fracturemedicineHumansMinimally Invasive Surgical ProceduresPolymethyl MethacrylateAgedCementbusiness.industryElectromyographyMinimally Invasive Surgical Proceduremedicine.diseaseequipment and suppliesInternalSurgeryProspective StudieThoracic vertebraeSurgeryCementoplastyNeurology (clinical)businessTomography X-Ray Computed030217 neurology & neurosurgeryOsteoporotic Fractures
researchProduct

Subjective and Objective Outcomes of Ankle Joint Arthrodesis with Either Ilizarov or Internal Fixation

2021

After arthroplasty, arthrodesis of the ankle joint is the most common method to treat advanced ankle osteoarthritis. The goal of the study was to assess the subjective and objective outcomes in 2 different types of fixation for ankle joint arthrodesis. We retrospectively assessed 47 patients who had undergone ankle joint arthrodesis with fixation either via an Ilizarov apparatus (group 1) (n = 21) or cannulated screws (group 2) (n = 26). The outcomes were measured by: (1) the quantity of analgesics administered, (2) the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, (3) general patient satisfaction, (4) the patients' decision to undergo the same procedure given an…

external fixationsatisfactionOrthopedics and Sports MedicineSurgeryscrew fixationblood transfusionJournal of Foot & Ankle Surgery
researchProduct

Le Fratture di Rotula

2015

Patellar fractures are relatively uncommon, accounting for approximately 1% of all fractures. Non-operative treatment represents the best choice for undisplaced patellar fractures. However, surgery becomes necessary when fractures are displaced by more than 2 mm, and may include open reduction and internal fixation. Accurate reduction and rigid fixation are required in order to allow early knee mobilization and to obtain a better clinical outcome. Several techniques have been described for patellar fracture fixation, such as tension band wiring, interfragmentary screw fixation, and the combination of screw fixation and cerclage. In this article up-to-date diagnosis, classification and treat…

musculoskeletal diseasesFibrous jointmedicine.medical_specialtybusiness.industryTension band wiringmedicine.medical_treatmentfiberwirefratture di rotula fratture di ginocchio trauma rotulamusculoskeletal systemmedicine.diseaseSurgeryScrew fixationFixation (surgical)medicine.anatomical_structurefrattureOrthopedic surgerySettore MED/33 - Malattie Apparato LocomotoreMedicineInternal fixationPatella fracturebusiness
researchProduct

Screw‐in‐screw fixation of fragility sacrum fractures provides high stability without loosening—biomechanical evaluation of a new concept

2020

Surgical treatment of fragility sacrum fractures with percutaneous sacroiliac (SI) screw fixation is associated with high failure rates. Turn-out is detected in up to 20% of the patients. The aim of this study was to evaluate a new screw-in-screw implant prototype for fragility sacrum fracture fixation. Twenty-seven artificial hemipelvises were assigned to three groups (n = 9) for instrumentation of an SI screw, the new screw-in-screw implant prototype, ora transsacral screw. Before implantation, a vertical osteotomy was set in zone 1 after Denis. All specimens were biomechanically tested to failure in upright position. Validated setup and test protocol were used for complex axial and torsi…

musculoskeletal diseasesSacrumMaterials sciencePercutaneousmedicine.medical_treatmentBone Screws0206 medical engineering02 engineering and technologyOsteotomyPelvisScrew fixationFracture Fixation InternalFractures Bone03 medical and health sciences0302 clinical medicineFragilitymedicineHumansOrthopedics and Sports MedicinePelvis030203 arthritis & rheumatologyOrthodonticsX-Raysequipment and suppliesmusculoskeletal systemSacrum020601 biomedical engineeringBiomechanical PhenomenaOsteotomyRadiographysurgical procedures operativemedicine.anatomical_structureSpinal FracturesStress MechanicalImplantTest protocolJournal of Orthopaedic Research
researchProduct

A new tool to improve pedicle screw placement accuracy in navigated spine surgery: A monocentric study

2021

Objective Navigated instrumented spine surgery is burden by a low but significant screw mispositioning risks, respectively, for the 2D imaging system from 15 to 40% and, for the 3D imaging system, ranging from 4.1 to 11.5%. The primary objective of this study was to demonstrate the efficacy of a new "screw-like" tool in order to further decrease pedicle screws mispositioning rate during vertebral navigated spine surgery. Materials and methods Between January and June 2019 an initial case series of 18 patients were enrolled. All patients underwent a pedicle screw fixation, both in thoracic (Th10-Th12) and lumbosacral (L1-S1) spine, using O-arm (Medtronic Navigation, Louisville, Colorado) and…

musculoskeletal diseasesmedicine.medical_specialty03 medical and health sciences0302 clinical medicineSpine surgeryImaging Three-DimensionalPedicle ScrewsMedicineHumansPedicle screw fixationPedicle screwNeuronavigationbusiness.industryNavigation systemmusculoskeletal systemSpineSurgerySurgery Computer-Assisted030220 oncology & carcinogenesisEquipment and suppliesSurgeryNeurosurgical proceduresNeurology (clinical)businessTomography X-Ray Computed030217 neurology & neurosurgeryLumbosacral joint
researchProduct